NEWS
Industry news
POSITION: HOME > Industry news
How to choose the air switch
PUBLISHER:Shanghai Moye Electric Co.,Ltd””RELEASE TIME:2017/7/13
Air switches are also commonly referred to as low voltage circuit breakers and are not limited to small DZ47 air switches. Which is currently used in industrial production automation of the largest electrical products, with many types, models and more features. This article Shanghai people electrical switch factory technical staff and we will talk about the general communist production should be how to choose the appropriate open products.
A: The common classification of air switches
(1) device type circuit breaker device type circuit breaker with insulated plastic shell, built-in contact system, interrupter and release, etc., can be manual or electric (for large capacity circuit breaker) closing. Has a higher breaking capacity and dynamic stability, a more complete selective protection, widely used in distribution lines. Currently used DZ15, DZ20, DZX10 and C45N (now has been upgraded to C65N) and other products. The C45N (C65N) circuit breaker has the advantages of small volume, high breaking ability, good current limiting performance, light operation, complete model specification and convenient combination of two-pole, three-pole and four-pole circuit breakers on the basis of unipolar structure , Widely used in 60A and below the civilian lighting branch and branch (more for residential users into the line switch and shopping street lighting switch).
(2) frame-type low-voltage circuit breaker frame-type circuit breakers generally larger capacity, with high short-circuit breaking capacity and high dynamic stability. Suitable for AC 50Hz, rated current 380V distribution network as the main protection of the trunk line. Frame-type circuit breakers mainly by the contact system, operating mechanism, over-current release, shunt release and undervoltage release, accessories and frames and other components, all components are installed in the frame structure of the base. At present, China has commonly used DW15, ME, AE, AH series of frame-type low-voltage circuit breakers. DWl5 series of circuit breakers is developed and produced in China, the whole series with 1000,1500,2500 and 4000A and several other models. ME, AE, AH series of circuit breakers are produced using the introduction of technology. They are more complete specifications (ME switching current rating from 630A ~ 5000A a total of 13 levels), rated breaking capacity stronger than DWl5, commonly used in low-voltage power distribution main protection.
(3) intelligent circuit breakers currently produced by the domestic intelligent circuit breaker and plastic shell type two. Frame-type intelligent circuit breakers are mainly used for intelligent automatic distribution system in the main circuit breaker, plastic shell intelligent circuit breaker is mainly used in the distribution network to allocate electricity and as a line and power equipment control and protection, but also Used as a three-phase cage induction motor control. Intelligent circuit breaker is characterized by the use of a microprocessor or microcontroller as the core of the intelligent controller (intelligent release), it not only has a variety of general circuit breaker protection, but also with real-time display circuit in a variety of Electrical parameters (current, voltage, power, power factor, etc.), on-line monitoring of the circuit, self-adjustment, measurement, test, self-diagnosis, communication and other functions, to a variety of protection functions of the operating parameters display, (DW), DW40, DW9 (AH), DWl8 (AE-S), DW48, DWl9 (3WE), DWl7 (ME), etc., can be stored in the nonvolatile memory. The frame series circuit breakers and intelligent molded case circuit breakers are equipped with ST series intelligent controller and supporting accessories. ST series intelligent controller is the key project of the national machinery department during the "Eighth Five-Year Plan" to "Ninth Five-Year Plan" period. Product performance indicators to the international advanced level of the 1990s. It uses modular support program, can be directly installed in the circuit breaker body, without repeating the secondary wiring, and a variety of options any combination.
Second: the principle of selection of air switch
1.) Determine the type and form of protection of the circuit breaker according to the requirements of the line protection. - Determine the choice of frame type, device type or current limit type.
2) The rated voltage of the circuit breaker UN shall be equal to or greater than the rated voltage of the protected circuit.
3) Breaker Undervoltage Release The rated voltage shall be equal to the rated voltage of the protected circuit.
4) The rated current of the circuit breaker and the rated current of the overcurrent release shall be greater than or equal to the calculated current of the protected circuit.
5) The limit breaking capacity of the circuit breaker shall be greater than the effective value of the maximum short circuit current of the line.
6) The protection characteristics of the upper and lower circuit breakers in the distribution line should be coordinated and the protection characteristics of the lower level should be located below the upper protection characteristic and not intersect.
7) The long delay trip current of the circuit breaker should be less than the permissible continuous current of the wire.
I hope this article for everyone to understand the air switch and how to buy can help!
A: The common classification of air switches
(1) device type circuit breaker device type circuit breaker with insulated plastic shell, built-in contact system, interrupter and release, etc., can be manual or electric (for large capacity circuit breaker) closing. Has a higher breaking capacity and dynamic stability, a more complete selective protection, widely used in distribution lines. Currently used DZ15, DZ20, DZX10 and C45N (now has been upgraded to C65N) and other products. The C45N (C65N) circuit breaker has the advantages of small volume, high breaking ability, good current limiting performance, light operation, complete model specification and convenient combination of two-pole, three-pole and four-pole circuit breakers on the basis of unipolar structure , Widely used in 60A and below the civilian lighting branch and branch (more for residential users into the line switch and shopping street lighting switch).
(2) frame-type low-voltage circuit breaker frame-type circuit breakers generally larger capacity, with high short-circuit breaking capacity and high dynamic stability. Suitable for AC 50Hz, rated current 380V distribution network as the main protection of the trunk line. Frame-type circuit breakers mainly by the contact system, operating mechanism, over-current release, shunt release and undervoltage release, accessories and frames and other components, all components are installed in the frame structure of the base. At present, China has commonly used DW15, ME, AE, AH series of frame-type low-voltage circuit breakers. DWl5 series of circuit breakers is developed and produced in China, the whole series with 1000,1500,2500 and 4000A and several other models. ME, AE, AH series of circuit breakers are produced using the introduction of technology. They are more complete specifications (ME switching current rating from 630A ~ 5000A a total of 13 levels), rated breaking capacity stronger than DWl5, commonly used in low-voltage power distribution main protection.
(3) intelligent circuit breakers currently produced by the domestic intelligent circuit breaker and plastic shell type two. Frame-type intelligent circuit breakers are mainly used for intelligent automatic distribution system in the main circuit breaker, plastic shell intelligent circuit breaker is mainly used in the distribution network to allocate electricity and as a line and power equipment control and protection, but also Used as a three-phase cage induction motor control. Intelligent circuit breaker is characterized by the use of a microprocessor or microcontroller as the core of the intelligent controller (intelligent release), it not only has a variety of general circuit breaker protection, but also with real-time display circuit in a variety of Electrical parameters (current, voltage, power, power factor, etc.), on-line monitoring of the circuit, self-adjustment, measurement, test, self-diagnosis, communication and other functions, to a variety of protection functions of the operating parameters display, (DW), DW40, DW9 (AH), DWl8 (AE-S), DW48, DWl9 (3WE), DWl7 (ME), etc., can be stored in the nonvolatile memory. The frame series circuit breakers and intelligent molded case circuit breakers are equipped with ST series intelligent controller and supporting accessories. ST series intelligent controller is the key project of the national machinery department during the "Eighth Five-Year Plan" to "Ninth Five-Year Plan" period. Product performance indicators to the international advanced level of the 1990s. It uses modular support program, can be directly installed in the circuit breaker body, without repeating the secondary wiring, and a variety of options any combination.
Second: the principle of selection of air switch
1.) Determine the type and form of protection of the circuit breaker according to the requirements of the line protection. - Determine the choice of frame type, device type or current limit type.
2) The rated voltage of the circuit breaker UN shall be equal to or greater than the rated voltage of the protected circuit.
3) Breaker Undervoltage Release The rated voltage shall be equal to the rated voltage of the protected circuit.
4) The rated current of the circuit breaker and the rated current of the overcurrent release shall be greater than or equal to the calculated current of the protected circuit.
5) The limit breaking capacity of the circuit breaker shall be greater than the effective value of the maximum short circuit current of the line.
6) The protection characteristics of the upper and lower circuit breakers in the distribution line should be coordinated and the protection characteristics of the lower level should be located below the upper protection characteristic and not intersect.
7) The long delay trip current of the circuit breaker should be less than the permissible continuous current of the wire.
I hope this article for everyone to understand the air switch and how to buy can help!